Error Message on the Pop up Message
NO DATA SELECTION INFORMATION FOUND
Data Selection information for this report has not been generated. Please contact your administrator
Error Messages in jas logs
[SPEC_NOT_FOUND] Unable to find OneWorld specification for REPORTSEL-R550411PT-KJG0001 (and/or)
[SPEC_NOT_FOUND] Unable to find OneWorld specification for PRINTINFO-R550411PT-KJG0001 (and/or)
[SPEC_NOT_FOUND] Unable to find OneWorld specification for REPORTSEQ-R550411PT-KJG0001 (and/or)
[SPEC_NOT_FOUND] Unable to find OneWorld specification for REPORTINFO-R550411PT-KJG001
Release : E811
Problem/Solution :
The serialized Specs generated by the Generator were inserted in to F989999 in Data Source A. But JAS server is looking into F989999 from a Data Source B.
So make sure both Generator and HTML Server are looking into the same Data Source
NO DATA SELECTION INFORMATION FOUND
Data Selection information for this report has not been generated. Please contact your administrator
Error Messages in jas logs
[SPEC_NOT_FOUND] Unable to find OneWorld specification for REPORTSEL-R550411PT-KJG0001 (and/or)
[SPEC_NOT_FOUND] Unable to find OneWorld specification for PRINTINFO-R550411PT-KJG0001 (and/or)
[SPEC_NOT_FOUND] Unable to find OneWorld specification for REPORTSEQ-R550411PT-KJG0001 (and/or)
[SPEC_NOT_FOUND] Unable to find OneWorld specification for REPORTINFO-R550411PT-KJG001
Release : E811
Problem/Solution :
The serialized Specs generated by the Generator were inserted in to F989999 in Data Source A. But JAS server is looking into F989999 from a Data Source B.
So make sure both Generator and HTML Server are looking into the same Data Source
2 comments:
Good tip. What version of E1 & Tools are you running?
Its 811 and 897